Параметр | Значение | Параметр | Значение |
---|---|---|---|
EC_Group | EC001446 |
Item |
E5CC |
E5EC |
E5AC |
|
---|---|---|---|---|
Power supply voltage |
A in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC |
|||
Operating voltage range |
85% to 110% of rated supply voltage |
|||
Power consumption |
6.5 VA max. at 100 to 240 VAC, and |
8.3 VA max. at 100 to 240 VAC, and |
9.0 VA max. at 100 to 240 VAC, and |
|
Sensor input |
|
|||
Input impedance |
Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB/THB.) |
|||
Control method |
ON/OFF control or 2-PID control (with auto-tuning) |
|||
Indication accuracy |
Thermocouple input: (±0.3% of indicated value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer input: (±0.2% of indicated value or ±0.8°C, whichever is greater) ±1 digit max. Analog input: ±0.2% FS ±1 digit max. CT input: ±5% FS ±1 digit max. |
Thermocouple input: (±0.3% of indicated value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer input: (±0.2% of indicated value or ±0.8°C, whichever is greater) ±1 digit max. Analog input: ±0.2% FS ±1 digit max. CT input: ±5% FS ±1 digit max. Potentiometer input: ±5% FS ±1 digit max. |
||
Auto-Tuning |
Yes, 40%/100% MV output limit selection. When using Heat/Cool: Automatic cool gain adjustment |
|||
Self-Tuning |
Yes |
|||
Control outputs |
Relay output |
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, |
SPST-NO, 250 VAC, 5 A (resistive load), |
|
Voltage output (for driving SSR) |
Output voltage: 12 VDC ±20% (PNP), max. load current: 21 mA, with short-circuit protection circuit |
Output voltage: 12 VDC ±20% (PNP), (The maximum load current is 21 mA for models with two control outputs.) |
||
Linear current output |
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000 |
|||
Auxiliary outputs |
Number of outputs |
2,3 |
4 |
|
Output specifications |
N.O. relay outputs, 250 VAC, |
N.O. relay outputs, 250 VAC, |
||
Event inputs |
Number of inputs |
2 or 4 or 6 max (depends on the model) |
||
External contact input specifications |
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min. |
|||
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. |
||||
Current flow: approx. 7 mA per contact |
||||
Setting method |
Digital setting using front panel keys or via Remote Software CX-Thermo V4.5 |
|||
Indication method |
11-segment digital display and individual indicators |
|||
Multi SP |
Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications. |
|||
Other functions |
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection (including SSR failure detection), 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple program, automatic cooling coefficient adjustment |
|||
Ambient operating temperature |
-10 to 55°C (with no condensation or icing) |
|||
Ambient operating humidity |
25% to 85% |
|||
Storage temperature |
-25 to 65°C (with no condensation or icing) |
|||
Degree of protection |
Front panel: IP66, Rear case: IP20, Terminals: IP00 |
|||
Sampling period |
50 ms |
|||
Size in mm (H×W×D) |
48×48×64 |
48×96×64 |
96×96×64 |
Item |
E5GC |
|
---|---|---|
Power supply voltage |
A in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC |
|
Sensor input |
|
|
Control method |
ON/OFF control or 2-PID control (with auto-tuning) |
|
Control output |
Relay output |
SPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA (reference value) |
Voltage output (for driving SSR) |
Output voltage 12 VDC ±20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit |
|
Linear current output |
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: Approx. 10,000 |
|
Auxiliary output |
Number of outputs |
1 or 2 (depends on model) |
Output specifications |
SPST-NO relay outputs, 250 VAC, 2 A (resistive load), |
|
Indication method |
11-segment digital displays and individual indicators |
|
Multi SP |
Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or serial communications. |
|
Other functions |
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations, temperature status display, simple programming, moving average of input value, display brightness setting, simple transfer output, and work bit message. |
|
Size in mm (H×W×D) |
24×48×93 |
Item |
E5DC |
|
---|---|---|
Power supply voltage |
A in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC |
|
Operating voltage range |
85% to 110% of rated supply voltage |
|
Power consumption |
4.9 VA max. at 100 to 240 VAC, and |
|
Sensor input |
|
|
Input impedance |
Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB/THB.) |
|
Control method |
ON/OFF control or 2-PID control (with auto-tuning) |
|
Indication accuracy |
Thermocouple input: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer input: (±0.2% of PV or ±0.8°C, whichever is greater) ±1 digit max. Analog input: ±0.2% FS ±1 digit max. CT input: ±5% FS ±1 digit max. |
|
Auto-Tuning |
Yes, 40%/100% MV output limit selection. When using Heat/Cool: Automatic cool gain adjustment |
|
Self-Tuning |
Yes |
|
Control outputs |
Relay output |
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA |
Voltage output (for driving SSR) |
Output voltage: 12 VDC ±20% (PNP), max. load current: 20 mA, with short-circuit protection circuit |
|
Linear current output |
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000 |
|
Auxiliary outputs |
Number of outputs |
2 (depends on model) |
Output specifications |
SPST-NO relay outputs: 250 VAC, 2 A (resistive load), |
|
Event inputs |
Number of inputs |
1 (depends on model) |
External contact input specifications |
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min. |
|
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. |
||
Current flow: approx. 7 mA per contact |
||
Setting method |
Digital setting using front panel keys |
|
Indication method |
11-segment digital displays and individual indicators |
|
Multi SP |
Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications. |
|
Other functions |
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (including SSR failure (HB) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, simple calculations, temperature status display, simple programming, moving average of input value, and display brightness setting |
|
Ambient operating temperature |
-10 to 55°C (with no condensation or icing), for 3-year warranty: -10 to 50°C (with no condensation or icing) |
|
Ambient operating humidity |
25% to 85% |
|
Storage temperature |
-25 to 65°C (with no condensation or icing) |
|
Degree of protection |
Main unit: IP20, Terminal unit: IP00 |
|
Sampling period |
50 ms |
|
Size in mm (H×W×D) |
96×22.5×85 |
Item |
E5AC |
E5CC |
E5DC |
E5EC |
E5GC |
---|---|---|---|---|---|
E58-CIFQ2 |
¢ |
¢ |
¢ |
¢ |
¢ |
E58-CIFQ2-E |
¢ |
- |
¢ |
¢ |
¢ |
Control Output |
Option no |
Option description |
Alarm outputs |
Order code |
|
---|---|---|---|---|---|
100 to 240 VAC |
24 VAC/DC |
||||
Out1: Relay Out2: non |
000 |
No option |
3 |
E5CC-RX3A5M-000 |
E5CC-RX3D5M-000 |
001 |
HB/HS alarm for 1-phase heaters, 2 EV inputs |
3 |
E5CC-RX3A5M-001 |
E5CC-RX3D5M-001 |
|
003 |
HB/HS alarm for 3-phase heaters, RS485 |
3 |
E5CC-RX3A5M-003 |
E5CC-RX3D5M-003 |
|
006 |
2 EV inputs, transfer output |
3 |
E5CC-RX3A5M-006 |
E5CC-RX3D5M-006 |
|
007 |
2 EV inputs, remote SP |
3 |
E5CC-RX3A5M-007 |
E5CC-RX3D5M-007 |
|
Out1: Voltage (pulse) Out2: non |
000 |
No option |
3 |
E5CC-QX3A5M-000 |
E5CC-QX3D5M-000 |
001 |
HB/HS alarm for 1-phase heaters, 2 EV inputs |
3 |
E5CC-QX3A5M-001 |
E5CC-QX3D5M-001 |
|
003 |
HB/HS alarm for 3-phase heaters, RS485 |
3 |
E5CC-QX3A5M-003 |
E5CC-QX3D5M-003 |
|
006 |
2 EV inputs, transfer output |
3 |
E5CC-QX3A5M-006 |
E5CC-QX3D5M-006 |
|
007 |
2 EV inputs, remote SP |
3 |
E5CC-QX3A5M-007 |
E5CC-QX3D5M-007 |
|
Out1: Linear current Out2: non |
000 |
No option |
3 |
E5CC-CX3A5M-000 |
E5CC-CX3D5M-000 |
004 |
RS485, 2 EV inputs |
3 |
E5CC-CX3A5M-004 |
E5CC-CX3D5M-004 |
|
006 |
2 EV inputs, transfer output |
3 |
E5CC-CX3A5M-006 |
E5CC-CX3D5M-006 |
|
007 |
2 EV inputs, remote SP |
3 |
E5CC-CX3A5M-007 |
E5CC-CX3D5M-007 |
Note: Other models with 2 control outputs, 4 EV inputs or with different kind of option combination are available on request. Please contact the local sales office for special request.
Control Output |
Option no |
Option description |
Alarm outputs |
Order code |
|
---|---|---|---|---|---|
100 to 240 VAC |
24 VAC/DC |
||||
Out1: Relay Out2: non |
0 |
No option |
2 |
E5CC-RX2ABM-000 |
E5CC-RX2DBM-000 |
1 |
HB/HS alarm for 1-phase heaters, 2 EV inputs |
2 |
E5CC-RX2ABM-001 |
E5CC-RX2DBM-001 |
|
2 |
HB/HS alarm for 1-phase heaters, RS485 |
2 |
E5CC-RX2ABM-002 |
E5CC-RX2DBM-002 |
|
4 |
RS485, 2 EV inputs |
2 |
E5CC-RX2ABM-004 |
E5CC-RX2DBM-004 |
|
6 |
2 EV inputs, Tranfer output |
2 |
E5CC-RX2ABM-006 |
E5CC-RX2DBM-006 |
|
Out1: Voltage (pulse) Out2: non |
0 |
No option |
2 |
E5CC-QX2ABM-000 |
E5CC-QX2DBM-000 |
1 |
HB/HS alarm for 1-phase heaters, 2 EV inputs |
2 |
E5CC-QX2ABM-001 |
E5CC-QX2DBM-001 |
|
2 |
HB/HS alarm for 1-phase heaters, RS485 |
2 |
E5CC-QX2ABM-002 |
E5CC-QX2DBM-002 |
|
4 |
RS485, 2 EV inputs |
2 |
E5CC-QX2ABM-004 |
E5CC-QX2DBM-004 |
|
6 |
2 EV inputs, Tranfer output |
2 |
E5CC-QX2ABM-006 |
E5CC-QX2DBM-006 |
Control Output |
Option no |
Option description |
Alarm outputs |
Order code |
|
---|---|---|---|---|---|
100 to 240 VAC |
24 VAC/DC |
||||
Out1: Relay Out2: non |
000 |
No option |
4 |
E5_C-RX4A5M-000 |
E5_C-RX4D5M-000 |
009 |
HB/HS alarm for 3-phase heaters, RS485, 2 EV inputs |
4 |
E5_C-RX4A5M-009 |
E5_C-RX4D5M-009 |
|
010 |
HB/HS alarm for 1-phase heaters, 4 EV inputs |
4 |
E5_C-RX4A5M-010 |
E5_C-RX4D5M-010 |
|
011 |
HB/HS alarm for 1-phase heaters, 6 EV inputs, remote SP, transfer output |
4 |
E5_C-RX4A5M-011 |
E5_C-RX4D5M-011 |
|
Out1: Voltage (pulse) Out2: non |
000 |
No option |
4 |
E5_C-QX4A5M-000 |
E5_C-QX4D5M-000 |
009 |
HB/HS alarm for 3-phase heaters, RS485, 2 EV inputs |
4 |
E5_C-QX4A5M-009 |
E5_C-QX4D5M-009 |
|
010 |
HB/HS alarm for 1-phase heaters, 4 EV inputs |
4 |
E5_C-QX4A5M-010 |
E5_C-QX4D5M-010 |
|
011 |
HB/HS alarm for 1-phase heaters, 6 EV inputs, remote SP, transfer output |
4 |
E5_C-QX4A5M-011 |
E5_C-QX4D5M-011 |
|
Out1: Linear current Out2: non |
000 |
No option |
4 |
E5_C-CX4A5M-000 |
E5_C-CX4D5M-000 |
004 |
2 EV inputs, RS485 |
4 |
E5_C-CX4A5M-004 |
E5_C-CX4D5M-004 |
|
014 |
RS485, 4 EV inputs, remote SP, transfer output |
4 |
E5_C-CX4A5M-014 |
E5_C-CX4D5M-014 |
|
Out1: Relay Out2: Relay Positional proportional control model |
000 |
No option |
4 |
E5_C-PR4A5M-000 |
E5_C-PR4D5M-000 |
004 |
2 EV inputs, RS485 |
4 |
E5_C-PR4A5M-004 |
E5_C-PR4D5M-004 |
|
014 |
RS485, 4 EV inputs, remote SP, transfer output |
4 |
E5_C-PR4A5M-014 |
E5_C-PR4D5M-014 |
Note: Other models with 2 control outputs or with different kind of option combination are available on request. Please contact the local sales office for special request. Replace “_” with “A” for E5AC or “E” for E5EC
Control Output |
Option no |
Option description |
Alarm outputs |
Order code |
|
---|---|---|---|---|---|
100 to 240 VAC |
24 VAC/DC |
||||
Out1: Relay Out2: non |
0 |
No option |
4 |
E5EC-RX4ABM-000 |
E5EC-RX4DBM-000 |
8 |
HB/HS alarm for 1-phase heaters, RS485, 2 EV inputs |
4 |
E5EC-RX4ABM-008 |
E5EC-RX4DBM-008 |
|
10 |
HB/HS alarm for 1-phase heaters, 4 EV inputs |
4 |
E5EC-RX4ABM-010 |
E5EC-RX4DBM-010 |
|
11 |
HB/HS alarm for 1-phase heaters, 6 EV inputs, remote SP, transfer output |
4 |
E5EC-RX4ABM-011 |
E5EC-RX4DBM-011 |
|
Out1: Voltage (pulse) Out2: non |
0 |
No option |
4 |
E5EC-QX4ABM-000 |
E5EC-QX4DBM-000 |
8 |
HB/HS alarm for 1-phase heaters, RS485, 2 EV inputs |
4 |
E5EC-QX4ABM-008 |
E5EC-QX4DBM-008 |
|
10 |
HB/HS alarm for 1-phase heaters, 4 EV inputs |
4 |
E5EC-QX4ABM-010 |
E5EC-QX4DBM-010 |
|
11 |
HB/HS alarm for 1-phase heaters, 6 EV inputs, remote SP, transfer output |
4 |
E5EC-QX4ABM-011 |
E5EC-QX4DBM-011 |
Note: Other models with 2 Alarm outputs are available on request. Please contact the local sales office for special request.
Control Output |
Terminal type |
Option no |
Option description |
Alarm outputs |
Order code |
|
---|---|---|---|---|---|---|
100 to 240 VAC |
24 VAC/DC |
|||||
Out1: Relay |
Screwless clamp |
000 |
No option |
1 |
E5GC-RX1ACM-000 |
E5GC-RX1DCM-000 |
015 |
RS485 |
1 |
E5GC-RX1ACM-015 |
E5GC-RX1DCM-015 |
||
024 |
2 EV inputs |
1 |
E5GC-RX1ACM-024 |
E5GC-RX1DCM-024 |
||
Out1: Voltage (pulse) |
Screwless clamp |
000 |
No option |
1 |
E5GC-QX1ACM-000 |
E5GC-QX1DCM-000 |
015 |
RS485 |
1 |
E5GC-QX1ACM-015 |
E5GC-QX1DCM-015 |
||
024 |
2 EV inputs |
1 |
E5GC-QX1ACM-024 |
E5GC-QX1DCM-024 |
||
Out1: Linear current |
Screwless clamp |
000 |
No option |
1 |
E5GC-CX1ACM-000 |
E5GC-CX1DCM-000 |
015 |
RS485 |
1 |
E5GC-CX1ACM-015 |
E5GC-CX1DCM-015 |
||
024 |
2 EV inputs |
1 |
E5GC-CX1ACM-024 |
E5GC-CX1DCM-024 |
Note: Other models with screw terminals, 0 or 2 Alarm outputs, 1 Event input or HBA alarm are available on request. Please contact the local sales office for special request.
Control Output |
Option no |
Option description |
Alarm outputs |
Order code |
|
---|---|---|---|---|---|
100 to 240 VAC |
24 VAC/DC |
||||
Out1: Relay |
000 |
No option |
2 |
E5DC-RX2ASM-000 |
E5DC-RX2DSM-000 |
002 |
HB/HS alarm for 1-phase heaters, RS485 |
2 |
E5DC-RX2ASM-002 |
E5DC-RX2DSM-002 |
|
017 |
HB/HS alarm for 1-phase heaters, 1 EV input |
2 |
E5DC-RX2ASM-017 |
E5DC-RX2DSM-017 |
|
Out1: Voltage (pulse) |
000 |
No option |
2 |
E5DC-QX2ASM-000 |
E5DC-QX2DSM-000 |
002 |
HB/HS alarm for 1-phase heaters, RS485 |
2 |
E5DC-QX2ASM-002 |
E5DC-QX2DSM-002 |
|
017 |
HB/HS alarm for 1-phase heaters, 1 EV input |
2 |
E5DC-QX2ASM-017 |
E5DC-QX2DSM-017 |
|
Out1: Linear current |
000 |
No option |
2 |
E5DC-CX2ASM-000 |
E5DC-CX2DSM-000 |
015 |
RS485 |
2 |
E5DC-CX2ASM-015 |
E5DC-CX2DSM-015 |
|
016 |
1 EV input |
2 |
E5DC-CX2ASM-016 |
E5DC-CX2DSM-016 |
Note: Other models with no Alarm output or with different kind of option combination are available on request. Please contact the local sales office for special request.
Option |
Order code |
---|---|
USB based configuration cable |
E58-CIFQ2, E58-CIFQ2-E (for E5AC, E5DC, E5EC and E5GC) |
PC based configuration and tuning software |
EST2-2C-MV4 |
Значительно снижает временные затраты и трудозатраты на настройку и управление параметрами температурного контроля.
CX-One - это объединенный комплект программного обеспечения с единым лицензионным номером. Установив однажды CX-One, пользователь сможет создавать, конфигурировать и программировать множество различных устройств, таких как ПЛК, программируемые терминалы или системы многоосного управления перемещениями, а также сети.
Склад Траскон (возможен самовывоз) - 1 шт.
Склад Omron Москва - 0 шт.
Склад Omron Европа - 0 шт.