XS5W-T421-GM2-SS Кабель EtherCAT с разъемами M12/M12 (прямого типа, вилка), экранированный, категории 5, 5 м
Уточните у наших менеджеров
Параметр | Значение | Параметр | Значение |
---|
Symbol |
Name |
Output capacity |
RUN output |
Order code |
||
---|---|---|---|---|---|---|
5 VDC |
24 VDC |
Total |
||||
① |
100 to 240 VAC power supply unit for NJ CPU |
6.0 A |
1.0 A |
30 W |
Supported |
NJ-PA3001 |
24 VDC power supply unit for NJ CPU |
NJ-PD3001 |
Note: Power supply units for the CJ Series cannot be used as a power supply for a CPU rack of the NJ System or as a power supply for an expansion rack.
Symbol |
CPU |
Program capacity |
Variables capacity |
Specifications |
Functionalities |
Number of axes |
Order code |
||||
---|---|---|---|---|---|---|---|---|---|---|---|
Sequence |
Motion |
DB connection |
Robotics |
SECS/GEM |
|||||||
② |
NJ501 |
20 MB |
2 MB: Retained 4 MB: Not retained |
I/O capacity: 2,560 points
CPU rack: 10 units max.
Expansion rack: (Up to 3 expansion racks)
40 units max. per system (CPU rack + 3 expansion racks)
Current consumption: 1.90 A at 5 VDC |
⬛ |
⬛ |
⬛ |
|
|
64 |
NJ501-1520 |
⬛ |
⬛ |
⬛ |
|
|
32 |
NJ501-1420 |
|||||
⬛ |
⬛ |
⬛ |
|
|
16 |
NJ501-1320 |
|||||
⬛ |
⬛ |
⬛ |
⬛ |
|
16 |
NJ501-4320 |
|||||
⬛ |
⬛ |
|
⬛ |
|
64 |
NJ501-4500 |
|||||
⬛ |
⬛ |
|
⬛ |
|
32 |
NJ501-4400 |
|||||
⬛ |
⬛ |
|
⬛ |
|
16 |
NJ501-4300 |
|||||
⬛ |
⬛ |
|
⬛ |
|
16 |
NJ501-4310 |
|||||
⬛ |
⬛ |
|
|
⬛ |
16 |
NJ501-1340 |
|||||
⬛ |
⬛ |
|
|
|
64 |
NJ501-1500 |
|||||
⬛ |
⬛ |
|
|
|
32 |
NJ501-1400 |
|||||
⬛ |
⬛ |
|
|
|
16 |
NJ501-1300 |
|||||
NJ301 |
5 MB |
0.5 MB: Retained 2 MB: Not retained |
⬛ |
⬛ |
|
|
|
8 |
NJ301-1200 |
||
⬛ |
⬛ |
|
|
|
4 |
NJ301-1100 |
|||||
NJ101 |
3 MB |
⬛ |
⬛ |
⬛ |
|
|
2 |
NJ101-1020 |
|||
⬛ |
|
⬛ |
|
|
0 |
NJ101-9020 |
|||||
⬛ |
⬛ |
|
|
|
2 |
NJ101-1000 |
|||||
⬛ |
|
|
|
|
0 |
NJ101-9000 |
Note: The end cover unit CJ1W-TER01 is included with the CPU unit.
Symbol |
Points |
Type |
Rated voltage |
Rated current |
Width |
Remarks |
Current consumption (A) |
Connection type |
Order code |
|
---|---|---|---|---|---|---|---|---|---|---|
5 VDC |
24 VDC |
|||||||||
③ |
8 |
AC input |
240 VAC |
10 mA |
31 mm |
− |
0.08 |
− |
M3 |
CJ1W-IA201 |
16 |
120 VAC |
7 mA |
31 mm |
− |
0.09 |
− |
M3 |
CJ1W-IA111 |
||
8 |
DC input |
24 VDC |
10 mA |
31 mm |
− |
0.08 |
− |
M3 |
CJ1W-ID201 |
|
16 |
24 VDC |
7 mA |
31 mm |
− |
0.08 |
− |
M3 |
CJ1W-ID211 |
||
31 mm |
Screwless |
CJ1W-ID211(SL) |
||||||||
16 |
24 VDC |
7 mA |
31 mm |
Fast-response (15 μ s is ON, 90 μ s is OFF) |
0.13 |
− |
M3 |
CJ1W-ID212 |
||
16 |
24 VDC |
7 mA |
31 mm |
Inputs start interrupt tasks in PLC program |
0.08 |
− |
M3 |
CJ1W-INT01 |
||
16 |
24 VDC |
7 mA |
31 mm |
Latches pulses down to 50 μ s pulse width |
0.08 |
− |
M3 |
CJ1W-IDP01 |
||
32 |
24 VDC |
4.1 mA |
20 mm |
− |
0.09 |
− |
Fujitsu |
CJ1W-ID231 |
||
32 |
24 VDC |
4.1 mA |
20 mm |
− |
0.09 |
− |
MIL |
CJ1W-ID232 |
||
32 |
24 VDC |
4.1 mA |
20 mm |
Fast-response (15 μ s is ON, 90 μ s is OFF) |
0.20 |
− |
MIL |
CJ1W-ID233 |
||
64 |
24 VDC |
4.1 mA |
31 mm |
− |
0.09 |
− |
Fujitsu |
CJ1W-ID261 |
||
64 |
24 VDC |
4.1 mA |
31 mm |
− |
0.09 |
− |
MIL |
CJ1W-ID262 |
||
8 |
Triac output |
250 VAC |
0.6 mA |
31 mm |
− |
0.22 |
− |
M3 |
CJ1W-OA201 |
|
8 |
Relay contact output |
250 VAC |
2 A |
31 mm |
− |
0.09 |
0.048 |
M3 |
CJ1W-OC201 |
|
31 mm |
Screwless |
CJ1W-OC201(SL) |
||||||||
16 |
250 VAC |
2 A |
31 mm |
− |
0.11 |
0.096 |
M3 |
CJ1W-OC211 |
||
31 mm |
Screwless |
CJ1W-OC211(SL) |
||||||||
8 |
DC output (sink) |
12 to 24 VDC |
2 A |
31 mm |
− |
0.09 |
− |
M3 |
CJ1W-OD201 |
|
8 |
12 to 24 VDC |
0.5 A |
31 mm |
− |
0.10 |
− |
M3 |
CJ1W-OD203 |
||
16 |
12 to 24 VDC |
0.5 A |
31 mm |
− |
0.10 |
− |
M3 |
CJ1W-OD211 |
||
31 mm |
Screwless |
CJ1W-OD211(SL) |
||||||||
16 |
24 VDC |
0.5 A |
31 mm |
Fast-response (15 μ s is ON, 80 μ s is OFF) |
0.15 |
− |
M3 |
CJ1W-OD213 |
||
32 |
12 to 24 VDC |
0.5 A |
20 mm |
− |
0.14 |
− |
Fujitsu |
CJ1W-OD231 |
||
32 |
12 to 24 VDC |
0.5 A |
20 mm |
− |
0.14 |
− |
MIL |
CJ1W-OD233 |
||
32 |
24 VDC |
0.5 A |
20 mm |
Fast-response (15 μ s is ON, 80 μ s is OFF) |
0.22 |
− |
MIL |
CJ1W-OD234 |
||
64 |
12 to 24 VDC |
0.3 A |
31 mm |
− |
0.17 |
− |
Fujitsu |
CJ1W-OD261 |
||
64 |
12 to 24 VDC |
0.3 A |
31 mm |
− |
0.17 |
− |
MIL |
CJ1W-OD263 |
||
8 |
DC output (source) |
24 VDC |
2 A |
31 mm |
Short-circuit protection |
0.11 |
− |
M3 |
CJ1W-OD202 |
|
8 |
24 VDC |
0.5 A |
31 mm |
Short-circuit protection |
0.10 |
− |
M3 |
CJ1W-OD204 |
||
16 |
24 VDC |
0.5 A |
31 mm |
Short-circuit protection |
0.10 |
− |
M3 |
CJ1W-OD212 |
||
31 mm |
Screwless |
CJ1W-OD212(SL) |
||||||||
32 |
24 VDC |
0.3 A |
20 mm |
Short-circuit protection |
0.15 |
− |
MIL |
CJ1W-OD232 |
||
64 |
24 VDC |
0.3 A |
31 mm |
− |
0.17 |
− |
MIL |
CJ1W-OD262 |
||
16 + 16 |
DC in + out (source) |
24 VDC |
0.5 A |
31 mm |
− |
0.13 |
− |
MIL |
CJ1W-MD232 |
|
16 + 16 |
DC in + out (sink) |
24 VDC |
0.5 A |
31 mm |
− |
0.13 |
− |
Fujitsu |
CJ1W-MD231 |
|
16 + 16 |
24 VDC |
0.5 A |
31 mm |
− |
0.13 |
− |
MIL |
CJ1W-MD233 |
||
32 + 32 |
24 VDC |
0.3 A |
31 mm |
− |
0.14 |
− |
Fujitsu |
CJ1W-MD261 |
||
32 + 32 |
24 VDC |
0.3 A |
31 mm |
− |
0.14 |
− |
MIL |
CJ1W-MD263 |
||
32 + 32 |
DC in + out (TTL) |
5 VDC |
35 mA |
31 mm |
− |
0.19 |
− |
MIL |
CJ1W-MD563 |
Note: MIL = Connector according to MIL-C-83503 (compatible with DIN 41651/IEC 60603-1).
Symbol |
Points |
Type |
Ranges |
Resolution |
Accuracy |
Conversion time |
Width |
Remarks |
Current (A) |
Connection type |
Order code |
|
---|---|---|---|---|---|---|---|---|---|---|---|---|
5 V |
24 V |
|||||||||||
③ |
4 |
Universal analog input |
0 to 5 V, 1 to 5 V, 0 to 10 V, 0 to 20 mA, 4 to 20 mA, K, J, T, L, R, S, B, Pt100, Pt1000, JPt100 |
V/l: 1/12,000 T/C: 0.1°C RTD: 0.1°C |
V: 0.3% I: 0.3% T/C: 0.3% RTD: 0.3% |
250 ms/4 points |
31 mm |
Universal inputs, with zero/span adjustment, configurable alarms, scaling, sensor error detection |
0.32 |
− |
M3 |
CJ1W-AD04U |
Screwless |
CJ1W-AD04U(SL) |
|||||||||||
4 |
Analog input |
0 to 5 V, 0 to 10 V, −10 to 10 V, 1 to 5 V, 4 to 20 mA |
1/8,000 |
V: 0.2% I: 0.4% |
250 μs/point |
31 mm |
Offset/gain adjustment, peak hold, moving average, alarms |
0.42 |
− |
M3 |
CJ1W-AD041-V1 |
|
Screwless |
CJ1W-AD041-V1(SL) |
|||||||||||
4 |
High-speed analog input |
1 to 5 V, 0 to 10 V, −5 to 5 V, −10 to 10 V, 4 to 20 mA |
1/40,000 |
V: 0.2% I: 0.4% |
35 μ s/4 points |
31 mm |
Direct conversion (CJ2H special instruction) |
0.52 |
− |
M3 |
CJ1W-AD042 |
|
8 |
Analog input |
1 to 5 V, 0 to 10 V, −10 to 10 V, 1 to 5 V, 4 to 20 mA |
1/8,000 |
V: 0.2% I: 0.4% |
250 μs/point |
31 mm |
Offset/gain adjustment, peak hold, moving average, alarms |
0.42 |
− |
M3 |
CJ1W-AD081-V1 |
|
Screwless |
CJ1W-AD081-V1(SL) |
|||||||||||
2 |
Analog output |
0 to 5 V, 0 to 10 V, −10 to 10 V, 1 to 5 V, 4 to 20 mA |
1/4,000 |
V: 0.3% I: 0.5% |
1 ms/point |
31 mm |
Offset/gain adjustment, output hold |
0.12 |
0.14 |
M3 |
CJ1W-DA021 |
|
Screwless |
CJ1W-DA021(SL) |
|||||||||||
4 |
Analog output |
1 to 5 V, 0 to 10 V, −10 to 10 V, 1 to 5 V, 4 to 20 mA |
1/4,000 |
V: 0.3% I: 0.5% |
1 ms/point |
31 mm |
Offset/gain adjustment, output hold |
0.12 |
0.2 |
M3 |
CJ1W-DA041 |
|
Screwless |
CJ1W-DA041(SL) |
|||||||||||
4 |
High-speed analog output |
1 to 5 V, 0 to 10 V, −10 to 10 V |
1/40,000 |
0.3% |
35 μ s/4 points |
31 mm |
Direct conversion (CJ2H special instruction) |
0.40 |
− |
M3 |
CJ1W-DA042V |
|
8 |
Voltage output |
1 to 5 V, 0 to 10 V, −10 to 10 V, 1 to 5 V |
1/8,000 |
0.3% |
250 μs/point |
31 mm |
Offset/gain adjustment, output hold |
0.14 |
0.14 |
M3 |
CJ1W-DA08V |
|
Screwless |
CJ1W-DA08V(SL) |
|||||||||||
8 |
Current output |
4 to 20 mA |
1/8,000 |
0.5% |
250 μs/point |
31 mm |
Offset/gain adjustment, output hold |
0.14 |
0.17 |
M3 |
CJ1W-DA08C |
|
Screwless |
CJ1W-DA08C(SL) |
|||||||||||
4 + 2 |
Analog |
1 to 5 V, 0 to 10 V, −10 to 10 V, 1 to 5 V, 4 to 20 mA |
1/8,000 |
in: 0.2% out: 0.3% |
1 ms/point |
31 mm |
Offset/gain adjustment, scaling, peak hold, moving average, alarms, output hold |
0.58 |
− |
M3 |
CJ1W-MAD42 |
|
Screwless |
CJ1W-MAD42(SL) |
|||||||||||
4 |
Universal analog input |
DC voltage, DC current, thermocouple, Pt100/Pt1000, potentiometer |
1/256,000 |
0.05% |
60 ms/4 points |
31 mm |
All inputs individually isolated, configurable alarms, maintenance functions, user-defined scaling, zero/span adjustment |
0.30 |
− |
M3 |
CJ1W-PH41U |
|
2 |
Process input |
4 to 20 mA, 0 to 20 mA, 0 to 10 V, −10 to 10 V, 0 to 5 V, −5 to 5 V, 1 to 5 V, 0 to 1.25 V, 1.25 to 1.25 V |
1/64,000 |
0.05% |
5 ms/point |
31 mm |
Configurable alarms, maintenance functions, user-defined scaling, zero/span adjustment, square root, totaliser |
0.18 |
0.09 |
M3 |
CJ1W-PDC15 |
|
6 |
Temperature control loops, thermocouple |
K-type (−200 to 1,300°C) J-type (−100 to 850ºC) |
0.1°C |
0.5% |
40 ms/point |
31 mm |
Basic I/O unit, setup by DIP switches, adjustable filtering |
0.22 |
− |
M3 |
CJ1W-TS561 |
|
Screwless |
CJ1W-TS561(SL) |
|||||||||||
6 |
Temperature control loops |
Pt100 (−200 to 650°C) Pt1000 (−200 to 650°C) |
0.1°C |
0.5% |
40 ms/point |
31 mm |
Basic I/O unit, setup by DIP switches, adjustable filtering |
0.25 |
− |
M3 |
CJ1W-TS562 |
|
Screwless |
CJ1W-TS562(SL) |
|||||||||||
2 |
Temperature control loops, thermocouple |
B, J, K, L, R, S, T |
0.1°C |
0.3% |
500 ms total |
31 mm |
Open collector NPN outputs |
0.25 |
− |
M3 |
CJ1W-TC003 |
|
2 |
Temperature control loops, thermocouple |
B, J, K, L, R, S, T |
0.1°C |
0.3% |
500 ms total |
31 mm |
Open collector PNP outputs |
0.25 |
− |
M3 |
CJ1W-TC004 |
|
2 |
Temperature control loops |
Pt100, JPt100 |
0.1°C |
0.3% |
500 ms total |
31 mm |
Open collector NPN outputs |
0.25 |
− |
M3 |
CJ1W-TC103 |
|
2 |
Temperature control loops |
Pt100, JPt100 |
0.1°C |
0.3% |
500 ms total |
31 mm |
Open collector PNP outputs |
0.25 |
− |
M3 |
CJ1W-TC104 |
Symbol |
Channels |
Type |
Signal type |
Width |
Remarks |
Current consumption (A) |
Connection type |
Order code |
|
---|---|---|---|---|---|---|---|---|---|
5 V |
24 V |
||||||||
③ |
2 |
500 kHz Counter |
24 V, line driver |
31 mm |
2 configurable digital inputs + outputs |
0.28 |
− |
Fujitsu |
CJ1W-CT021 |
4 |
100 kHz Counter |
Line driver, 24 V |
Target values trigger interrupt to CPU |
0.32 |
− |
1 × MIL (40 pt) |
CJ1W-CTL41-E |
Symbol |
Type |
Ports |
Data transfer |
Protocols |
Width |
Current consumption (A) |
Connection type |
Order code |
|
---|---|---|---|---|---|---|---|---|---|
5 V |
24 V |
||||||||
③ |
Serial communications units |
2 × RS-232C |
High-speed |
CompoWay/F, host link, NT link, Modbus, user-defined |
31 mm |
0.28 |
− |
9 pin D-Sub |
CJ1W-SCU22 |
2 × RS-422A/RS-485 |
31 mm |
0.28 |
− |
9 pin D-Sub |
CJ1W-SCU32 |
||||
1 × RS-232C + 1 × RS-422/RS-485 |
31 mm |
0.28 |
− |
9 pin D-Sub |
CJ1W-SCU42 |
||||
EtherNet/IP |
1 × 100 Base-Tx |
− |
EtherNet/IP, UDP, TCP/IP, FTP server, SNTP, SNMP |
31 mm |
0.41 |
− |
RJ45 |
CJ1W-EIP21 |
|
EtherCAT |
2 × 100 Base-Tx |
− |
EtherCAT |
31 mm |
0.34 |
− |
RJ45 |
CJ1W-ECT21 |
|
DeviceNet |
1 × CAN |
− |
DeviceNet |
31 mm |
0.29 |
− |
5-p detachable |
CJ1W-DRM21 |
|
CompoNet |
4-wire, data + power to slaves (Master) |
− |
CompoNet (CIP-based) |
31 mm |
0.4 |
− |
4-p detachable IDC or screw |
CJ1W-CRM21 |
|
PROFIBUS-DP |
1 × RS-485 (Master) |
− |
DP, DPV1 |
31 mm |
0.40 |
− |
9 pin D-Sub |
CJ1W-PRM21 |
|
1 × RS-485 (Slave) |
− |
DP |
31 mm |
0.40 |
− |
CJ1W-PRT21 |
|||
PROFINET-IO |
1 × 100 Base-Tx |
− |
PROFINET-IO controller, FINS/UDP |
31 mm |
0.42 |
− |
RJ45 |
CJ1W-PNT21 |
|
RS-422A converter accessory |
RS-232C to RS-422A/RS-485 signal converter. Mounts directly on serial port |
9 pin D-Sub to screw clamp terminals |
CJ1W-CIF11 |
Symbol |
Type |
Specifications |
Current consumption (A) |
Order code |
||||
---|---|---|---|---|---|---|---|---|
Connected ID systems |
No. of connected |
External power supply |
No. of unit numbers allocated |
|||||
5 V |
24 V |
|||||||
③ |
ID sensor units |
V680-Series RFID system |
1 |
Not required |
1 |
0.26 |
0.13 |
CJ1W-V680C11 |
2 |
2 |
0.32 |
0.26 |
CJ1W-V680C12 |
Note: The data transfer function using intelligent I/O commands can not be used.
Symbol |
Name |
Connecting cable |
Connected Unit |
Width |
Current consumption (A) |
Order code |
|
---|---|---|---|---|---|---|---|
5 V |
24 V |
||||||
④ |
CJ-Series I/O control unit |
CS1W-CN__3 |
CJ1W-II101 |
20 mm |
0.02 A |
− |
CJ1W-IC101 |
Note: Mount to the right of the power supply unit.
Symbol |
Name |
Connecting cable |
Width |
Current consumption (A) |
Order code |
|
---|---|---|---|---|---|---|
5 V |
24 V |
|||||
⑤ |
CJ-Series I/O interface unit |
CS1W-CN__3 |
31 mm |
0.13 A |
− |
CJ1W-II101 |
Note: Mount to the right of the power supply unit.
Symbol |
Name |
Specifications |
Order code |
|
---|---|---|---|---|
⑥ |
I/O connecting cable |
Connects an I/O control unit on NJ series CPU rack to an I/O interface unit on a NJ series expansion rack. or Connects an I/O interface unit on NJ series expansion rack to an I/O interface unit on another NJ series expansion rack. |
Cable length: 0.3 m |
CS1W-CN313 |
Cable length: 0.7 m |
CS1W-CN713 |
|||
Cable length: 2 m |
CS1W-CN223 |
|||
Cable length: 3 m |
CS1W-CN323 |
|||
Cable length: 5 m |
CS1W-CN523 |
|||
Cable length: 10 m |
CS1W-CN133 |
|||
Cable length: 12 m |
CS1W-CN133-B2 |
Symbol |
Appearance |
Name |
No. of ports |
Power supply voltage |
Current consumption (A) |
Dimensions (W × D × H) |
Weight |
Order code |
---|---|---|---|---|---|---|---|---|
⑦ |
|
EtherCAT junction slave |
3 |
20.4 to 28.8 VDC (24 VDC −15 to 20%) |
0.08 |
25 mm × 78 mm × 90 mm |
165 g |
GX-JC03 |
|
6 |
0.17 |
48 mm × 78 mm × 90 mm |
220 g |
GX-JC06 |
Symbol |
Appearance |
Specifications |
Accessories |
Current consumption (A) |
Order code |
||
---|---|---|---|---|---|---|---|
Functions |
No. of ports |
Failure detection |
|||||
⑧ |
|
Quality of Service (QoS): EtherNet/IP control data priority. Failure detection: Broadcast storm and LSI error detection 10/100 BASE-TX, Auto-Negotiation |
3 |
No |
Power supply connector |
0.22 |
W4S1-03B |
5 |
No |
W4S1-05B |
|||||
5 |
Yes |
Power supply connector and connector for informing error |
W4S1-05C |
Symbol |
Item |
Manufacturer |
Color |
Cable |
Order code |
||
---|---|---|---|---|---|---|---|
⑨ |
EtherCAT cable |
Cat 5e, AWG22, 2-pair cable M12/Smartclick connectors Improved shield for EtherCAT |
Standard type Cable with connectors on both ends (M12 straight/M12 straight) |
OMRON |
Black |
0.5 |
XS5W-T421-BM2-SS |
1 |
XS5W-T421-CM2-SS |
||||||
2 |
XS5W-T421-DM2-SS |
||||||
3 |
XS5W-T421-EM2-SS |
||||||
5 |
XS5W-T421-GM2-SS |
||||||
10 |
XS5W-T421-JM2-SS |
||||||
Rugged type Cable with connectors on both ends (M12 straight/RJ45) |
Black |
0.5 |
XS5W-T421-BMCSS |
||||
1 |
XS5W-T421-CMC-SS |
||||||
2 |
XS5W-T421-DMC-SS |
||||||
3 |
XS5W-T421-EMC-SS |
||||||
5 |
XS5W-T421-GMC-SS |
||||||
10 |
XS5W-T421-JMC-SS |
||||||
Ethernet/EtherCAT |
Cat 6a, AWG27, 4-pair cable Cable sheath material: LSZH |
Standard type Cable with connectors on both ends (RJ45/RJ45) |
Yellow |
0.2 |
XS6W-6LSZH8SS20CM-Y |
||
0.3 |
XS6W-6LSZH8SS30CM-Y |
||||||
0.5 |
XS6W-6LSZH8SS50CM-Y |
||||||
1 |
XS6W-6LSZH8SS100CM-Y |
||||||
1.5 |
XS6W-6LSZH8SS150CM-Y |
||||||
2 |
XS6W-6LSZH8SS200CM-Y |
||||||
3 |
XS6W-6LSZH8SS300CM-Y |
||||||
5 |
XS6W-6LSZH8SS500CM-Y |
||||||
7.5 |
XS6W-6LSZH8SS750CM-Y |
||||||
10 |
XS6W-6LSZH8SS1000CM-Y |
||||||
15 |
XS6W-6LSZH8SS1500CM-Y |
||||||
20 |
XS6W-6LSZH8SS2000CM-Y |
||||||
Green |
0.2 |
XS6W-6LSZH8SS20CM-G |
|||||
0.3 |
XS6W-6LSZH8SS30CM-G |
||||||
0.5 |
XS6W-6LSZH8SS50CM-G |
||||||
1 |
XS6W-6LSZH8SS100CM-G |
||||||
1.5 |
XS6W-6LSZH8SS150CM-G |
||||||
2 |
XS6W-6LSZH8SS200CM-G |
||||||
3 |
XS6W-6LSZH8SS300CM-G |
||||||
5 |
XS6W-6LSZH8SS500CM-G |
||||||
7.5 |
XS6W-6LSZH8SS750CM-G |
||||||
10 |
XS6W-6LSZH8SS1000CM-G |
||||||
15 |
XS6W-6LSZH8SS1500CM-G |
||||||
20 |
XS6W-6LSZH8SS2000CM-G |
||||||
Cat 5e, AWG26, 4-pair cable Cable sheath material: PUR |
Standard type Cable with connectors on both ends (RJ45/RJ45) |
Green |
0.5 |
XS6W-5PUR8SS50CM-G |
|||
1 |
XS6W-5PUR8SS100CM-G |
||||||
1.5 |
XS6W-5PUR8SS150CM-G |
||||||
2 |
XS6W-5PUR8SS200CM-G |
||||||
3 |
XS6W-5PUR8SS300CM-G |
||||||
5 |
XS6W-5PUR8SS500CM-G |
||||||
7.5 |
XS6W-5PUR8SS750CM-G |
||||||
10 |
XS6W-5PUR8SS1000CM-G |
||||||
15 |
XS6W-5PUR8SS1500CM-G |
||||||
20 |
XS6W-5PUR8SS2000CM-G |
||||||
⑨ |
Ethernet/EtherCAT |
Cat 5e, AWG22, 2-pair cable |
Rugged type Cable with connectors on both ends (RJ45/RJ45) |
OMRON |
Grey |
0.3 |
XS5W-T421-AMD-K |
0.5 |
XS5W-T421-BMD-K |
||||||
1 |
XS5W-T421-CMD-K |
||||||
2 |
XS5W-T421-DMD-K |
||||||
3 |
XS5W-T421-EMD-K |
||||||
5 |
XS5W-T421-GMD-K |
||||||
10 |
XS5W-T421-JMD-K |
||||||
15 |
XS5W-T421-KMD-K |
||||||
Rugged type Cable with connectors on both ends (M12 straight/RJ45) |
Grey |
0.3 |
XS5W-T421-AMC-K |
||||
0.5 |
XS5W-T421-BMC-K |
||||||
1 |
XS5W-T421-CMC-K |
||||||
2 |
XS5W-T421-DMC-K |
||||||
3 |
XS5W-T421-EMC-K |
||||||
5 |
XS5W-T421-GMC-K |
||||||
10 |
XS5W-T421-JMC-K |
||||||
15 |
XS5W-T421-KMC-K |
||||||
Cat 5e, AWG22, 2-pair cable |
Rugged type Cable with connectors on both ends (M12 L right angle/RJ45) |
Grey |
0.3 |
XS5W-T422-AMC-K |
|||
0.5 |
XS5W-T422-BMC-K |
||||||
1 |
XS5W-T422-CMC-K |
||||||
2 |
XS5W-T422-DMC-K |
||||||
3 |
XS5W-T422-EMC-K |
||||||
5 |
XS5W-T422-GMC-K |
||||||
10 |
XS5W-T422-JMC-K |
||||||
15 |
XS5W-T422-KMC-K |
||||||
Ethernet installation cable |
Cat 5, SF/UTP, 4 × 2 × AWG 24/1 (solid core), Polyurethane (PUR) |
Weidmüller |
Green |
100 |
WM IE-5IC4x2xAWG24/1-PUR |
||
Cat 5, SF/UTP, 4 × 2 × AWG 26/7 (stranded core), Polyurethane (PUR) |
Green |
100 |
WM IE-5IC4x2xAWG26/7-PUR |
||||
Connectors |
RJ45 metallic connector For AWG22 to AWG26 |
|
− |
− |
WM IE-T0-RJ45-FH-BK |
||
RJ45 plastic connector For AWG22 to AWG24 |
|
OMRON |
− |
− |
XS6G-T421-1 |
||
RJ45 socket |
DIN-rail mount socket to terminate installation cable in the cabinet |
Weidmüller |
− |
− |
WM IE-T0-RJ45-FJ-B |
Note: Please be careful while cable processing, for EtherCAT, connectors on both ends should be shield connected and for EtherNet/IP, connectors on only one end should be shield connected.
Appearance |
Name |
Area |
Type |
Order code |
---|---|---|---|---|
|
WE70 FA wireless LAN units |
Europe |
Access point (Master) |
WE70-AP-EU |
Client (Slave) |
WE70-CL-EU |
|||
Directional magnetic-base antenna |
1 set with two antennas, 2.4 GHz/5 GHz Dual-band compatible |
WE70-AT001H |
||
DIN rail mounting bracket |
For TH35 7.5 |
WT30-FT001 |
||
For TH35 15 |
WT30-FT002 |
|||
Antenna extension cable |
5 m |
WE70-CA5M |
Note: Special versions are available for USA, Canada, China and Japan.
Appearance |
Specifications |
Order code |
|
---|---|---|---|
|
SD memory card |
2 GB |
HMC-SD291 |
4 GB |
HMC-SD491 |
||
|
DIN track |
Length: 0.5 m; height: 7.3 mm |
PFP-50N |
Length: 1 m; height: 7.3 mm |
PFP-100N |
||
Length: 1 m; height: 16 mm |
PFP-100N2 |
||
|
End plate to secure the units on the DIN track (2 pieces are included with the CPU unit and I/O interface unit) |
PFP-M (2 pcs) |
|
|
Battery for NX7/NJ CPU unit (The battery is included with the CPU unit) |
CJ1W-BAT01 |
|
|
End cover (The end cover is included with each CPU unit and I/O interface unit) |
CJ1W-TER01 |
Symbol |
Specifications |
Order code |
|
---|---|---|---|
⑩ |
Sysmac Studio |
SYSMAC-SE2___ |
|
License for the SECS/GEM configurator |
Software to make HSMS, SECSII and GEM settings for the NJ501 CPU units with SECS/GEM communications |
WS02-GCTL1 |
1. The NJ501-4310 CPU unit only supports one Delta robot.
2. Accuracy for voltage and current inputs/outputs as percentage of full scale and typical value at 25°C ambient temperature (consult the operation manual for details)
Accuracy for temperature inputs/outputs as percentage of process value and typical value at 25°C ambient temperature (consult the operation manual for details)
3. Supported only by the EtherNet/IP units with unit version 2.1 or later, CPU units with unit version 1.01 or later and the Sysmac Studio version 1.02 or higher.
4. Supported only by the CPU units with unit version 1.10 or higher and the Sysmac Studio version 1.13 or higher.
5. Supported only by the CPU units with unit version 1.01 or higher and the Sysmac Studio version 1.02 or higher.
6. To use a V680-H01 antenna, refer to the V680 Series RFID system catalog (Cat. No. Q151)
7. The lineup features low smoke zero halogen cables for in-cabinet use and PUR cables for out-of-cabinet use.
8. This cable is available in yellow, green and blue colors.
9. For the NJ101-_000 CPU units, Sysmac Studio version 1.13 or higher is needed.
10. For the NJ101-_020 CPU units (with database connection), Sysmac Studio version 1.14 or higher is needed.
11. Refer to the Sysmac Studio datasheet (Cat. No. SysCat_I181E) for detailed information or contact your OMRON representative
12. SECS/GEM configurator files are included in the Sysmac Studio standard edition DVD.
Созданное для обеспечения полного управления системой автоматизации, программное обеспечение Sysmac Studio объединяет в простом интерфейсе конфигурирование, программирование и контроль.
Склад Траскон (возможен самовывоз) - 2 шт.
Склад Omron Москва - 48 шт.
Склад Omron Европа - 73 шт.
Склад Траскон (возможен самовывоз) - 1 шт.
Склад Omron Москва - 0 шт.
Склад Omron Европа - 0 шт.
Склад Траскон (возможен самовывоз) - 2 шт.
Склад Omron Москва - 16 шт.
Склад Omron Европа - 88 шт.
Склад Траскон (возможен самовывоз) - 3 шт.
Склад Omron Москва - 0 шт.
Склад Omron Европа - 0 шт.